Home / Products / Syringe Filter / PVDF Syringe Filter

PVDF Syringe Filters Custom

Welch Materials, Inc.

Welch Materials, Inc. is a professional China PVDF Syringe Filters Manufacturers and PVDF Syringe Filters Factory in china, It's was established in August 2003 with its headquarter are currently located in Songjiang, Shanghai. It also has production and R&D facilities in Jinhua, Zhejiang and Nanjing, Jiangsu. We also have set subsidiaries in the United States, India and Canada. We are multinational company that develops and manufactures laboratory products including PVDF Syringe Filters, SPE cartridges, HPLC Column.Welch Materials, Inc. has integrated research, production, sales, and service, dedicated to become a one-stop laboratory suppliers in the world. Its products are widely used in industries such as biomedicine, food safety testing, environmental monitoring, and fine chemicals, which are essential to people's livelihood. By implementing rigorous quality inspection processes and adhering to strict standards, the company ensures that every product produced is compliant, meeting the highest laboratory requirements.
BRANDSTORY
About Us
Consumables Lab Biological

System
Certification

International system certification, effectively consolidate the competitiveness of the enterprise.

Contcat Us For A Quote Now.

For any inquiries from the customers,we will reply with the most professional and most reasonable price in time.

NEWS

*Industry Knowledge Development*
Polyvinylidene fluoride (PVDF) syringe filters are commonly used in laboratory settings for filtration applications. PVDF is a hydrophobic, thermoplastic fluoropolymer known for its excellent chemical resistance and low protein binding properties. These filters are designed to remove particulates and microorganisms from liquid samples, providing a clear and filtered solution.

Here are some key features and benefits of PVDF syringe filters:
1.Chemical compatibility: PVDF is resistant to a wide range of solvents, acids, bases, and organic compounds, making it suitable for filtering a variety of solutions.
2.Low protein binding: PVDF filters have a low affinity for proteins, minimizing sample loss and ensuring accurate analysis in applications such as protein purification and biological sample filtration.
3.Hydrophobicity: PVDF is a hydrophobic material, which means it repels water. This property makes PVDF syringe filters ideal for filtration of aqueous solutions, as they prevent water from passing through while allowing the filtrate to flow.
4.High flow rates: PVDF syringe filters typically have a fast flow rate, enabling quick and efficient filtration of samples.
5.Sterile options: PVDF syringe filters are available in both sterile and non-sterile versions, allowing for filtration of samples requiring aseptic conditions.
6.Compatibility with organic solvents: PVDF filters can be used with a variety of organic solvents, such as alcohols, ketones, and esters, expanding their versatility in chemical and pharmaceutical applications.

When using PVDF (Polyvinylidene fluoride) syringe filters, there are several important factors to consider to ensure proper usage and optimal results. Here are some key points to pay attention to:
1.Compatibility: PVDF syringe filters are versatile and suitable for a wide range of applications. However, it is important to ensure compatibility with the sample and solvent being filtered. PVDF is generally resistant to a wide range of chemicals, but some strong solvents, such as certain organic solvents, may not be suitable. Always check the chemical compatibility of PVDF with your specific sample or solvent.
2.Pore Size Selection: PVDF syringe filters are available in different pore sizes, typically ranging from 0.1 μm to 0.45 μm. The choice of pore size depends on the size of the particles or microorganisms you want to remove. Smaller pore sizes provide better filtration efficiency but may have a slower flow rate. Consider the size of the particles you need to remove and balance it with the desired flow rate.
3.Filtration Pressure and Flow Rate: PVDF syringe filters can withstand higher pressures compared to other membrane materials, allowing for faster filtration. However, it is important to operate within the recommended pressure limits specified by the manufacturer to avoid membrane damage or rupture. Excessive pressure can lead to a higher flow rate but may also compromise the integrity of the filter.
4.Wetting: PVDF membranes are naturally hydrophobic, which means they repel water. Before using PVDF syringe filters, they need to be pre-wetted with a compatible solvent (typically alcohol or a water-miscible organic solvent) to improve their wetting properties. This step helps to minimize any potential loss of sample during filtration and ensures efficient filtration.
5.Sample Volume: Consider the volume of your sample and choose an appropriately sized syringe filter. Using a filter with a smaller surface area than required may result in clogging or decreased filtration efficiency.
6.Filtration Technique: Proper technique during filtration is essential to achieve accurate and reproducible results. Use a consistent and controlled force when applying pressure to the syringe plunger to avoid bursting the filter or damaging the membrane.
7.Sterility: If sterility is a concern, ensure that the PVDF syringe filters you choose are sterile or can be sterilized. Sterile filters are pre-sterilized using methods like gamma irradiation or ethylene oxide treatment. Non-sterile filters may require autoclaving or other sterilization methods before use.
8.Quality and Manufacturer: Choose high-quality PVDF syringe filters from reputable manufacturers to ensure reliable and consistent performance. It is important to follow the manufacturer's instructions and guidelines for usage and storage.

Overall, PVDF syringe filters are reliable, robust, and widely used for various laboratory filtration needs, particularly in applications involving aggressive solvents, biological samples, or proteins.